NTECsystems's Space http://ntecsystems.posterous.com Most recent posts at NTECsystems's Space posterous.com Thu, 20 Sep 2012 10:52:18 -0700 Walhalla Food Store http://ntecsystems.posterous.com/walhalla-food-store http://ntecsystems.posterous.com/walhalla-food-store

28' x 40' smooth cap sheet with elastomeric coating a few years old but failing because of expansion and contraction in areas. One fixed HVAC and three RTU's for refrigeration sitting on blocks. I recommended pads for these unit. Customer wants to close drains and send water to open edge where shingled roof is and also to rear where gutters are.

Permalink | Leave a comment  »

]]>
http://files.posterous.com/user_profile_pics/2054046/NTEC3.jpg http://posterous.com/users/lD4AHHnGYQjvs NTEC Systems NTECsystems NTEC Systems
Thu, 26 Jul 2012 03:54:11 -0700 Global 335666-03 / Leslie's 420. http://ntecsystems.posterous.com/global-335666-03-leslies-420 http://ntecsystems.posterous.com/global-335666-03-leslies-420

Pictures of repairs at Leslie's store 420. Before, during and after. Leaks around HVAC units corrected by flashing in units and coating roofing area around units. Note that the HVAC unit recentlly replaced is also causing water infiltration via pan and also electrical conduit has collapsed tearing open and exposing wiring. This should be secured to unit and conduit repaired and sealed.

Permalink | Leave a comment  »

]]>
http://files.posterous.com/user_profile_pics/2054046/NTEC3.jpg http://posterous.com/users/lD4AHHnGYQjvs NTEC Systems NTECsystems NTEC Systems
Tue, 03 Jul 2012 13:55:00 -0700 223 / 225 Main Street, FM-SC. http://ntecsystems.posterous.com/223-225-main-street-fm-sc http://ntecsystems.posterous.com/223-225-main-street-fm-sc

Gentlemen please review the following photos of before and after shots on 223 and 225 Main Street, FM-SC. The two roofing systems were combined previously as you will notice with the 225 SPF roof terminating over the 223 EPDM system. After we completed restoration on 225 this was still the situations. Sometime around Dec. 2011 the roofing system on 223 was replaced with a TPO system. We suspect a few things here but the main thing is that we are concerned about our roofing system on 225 not being terminated. I also suspect trade damage on our SPF roof 225 related to weight and certainly foreign objects and debris that has littered the roofing system after completion of replacement on 223. The 225 owner has concerns about encroachment but we suspect the bent metal to only conceal the termination or lack of termination at this new parapet wall that was constructed. I can not see under this metal cap to inspect and was not contacted to create a new termination on my customers SPF roof 225 and we are gravely concerned that either there is no termination or improper termination attempted by someone else using unsupported products. I attempted to contact the other contractor 3 times a day for 2 days with voice mail full and no returned call. I was asking that this metal be removed for inspection and possible a quote directly to the other parties to provide a service terminating the 225 roofing system properly. This new parapet system was inspected by Wayne Hunter per my request and concerns were expressed on-site that this was not acceptable. I have turned this over the the City and the owner and have very little else that I can do other than provide these pictures and complete repairs if and when requested. Please understand that NTEC Systems is unable to provide warranty services an the roofing system at 225 Main Street Fort Mill SC until we are able to inspect this area, provide proper termination and rest assured that the City of Fort Mill is satisfied with code requirements on whatever they are expecting at this new parapet wall.

   

Permalink | Leave a comment  »

]]>
http://files.posterous.com/user_profile_pics/2054046/NTEC3.jpg http://posterous.com/users/lD4AHHnGYQjvs NTEC Systems NTECsystems NTEC Systems
Fri, 29 Jun 2012 08:55:49 -0700 Dollar General http://ntecsystems.posterous.com/dollar-general http://ntecsystems.posterous.com/dollar-general

Subway leak investigation

Permalink | Leave a comment  »

]]>
http://files.posterous.com/user_profile_pics/2054046/NTEC3.jpg http://posterous.com/users/lD4AHHnGYQjvs NTEC Systems NTECsystems NTEC Systems
Thu, 28 Jun 2012 12:41:00 -0700 Leslies Poolmart 420 http://ntecsystems.posterous.com/second-global http://ntecsystems.posterous.com/second-global

Here are the rest of the pic...

Permalink | Leave a comment  »

]]>
http://files.posterous.com/user_profile_pics/2054046/NTEC3.jpg http://posterous.com/users/lD4AHHnGYQjvs NTEC Systems NTECsystems NTEC Systems
Thu, 28 Jun 2012 12:27:00 -0700 Leslies Poolmart 420 (2) http://ntecsystems.posterous.com/global http://ntecsystems.posterous.com/global

Can't send them via computer so here you go.

Permalink | Leave a comment  »

]]>
http://files.posterous.com/user_profile_pics/2054046/NTEC3.jpg http://posterous.com/users/lD4AHHnGYQjvs NTEC Systems NTECsystems NTEC Systems
Fri, 15 Jun 2012 05:58:26 -0700 Reidenbaugh http://ntecsystems.posterous.com/reidenbaugh http://ntecsystems.posterous.com/reidenbaugh

What the hell... to much coating??? Not enough primer??? These areas are not adhered to the membrane.

Permalink | Leave a comment  »

]]>
http://files.posterous.com/user_profile_pics/2054046/NTEC3.jpg http://posterous.com/users/lD4AHHnGYQjvs NTEC Systems NTECsystems NTEC Systems
Thu, 14 Jun 2012 05:27:44 -0700 Repair number 3 Readinbaugh. http://ntecsystems.posterous.com/repair-number-3-readinbaugh http://ntecsystems.posterous.com/repair-number-3-readinbaugh

Here are pictures of number 3. This one is different. Smaller small blisters and also one area where the top coat separated from the base coat. I think this is because instead on a large pond this area is 3 smaller areas, in a row but seams between them. These area have not advanced to the degree of failure as number 1 and 2. In other words water is not under the coating system, on top. I did not even find these blisters untilled I cleaned the dirt out of the area and then noticed them. These are tougher to remove also but smaller. Lets talk about the base coat. I can't pull it up if it aspirated from the top coat.

Permalink | Leave a comment  »

]]>
http://files.posterous.com/user_profile_pics/2054046/NTEC3.jpg http://posterous.com/users/lD4AHHnGYQjvs NTEC Systems NTECsystems NTEC Systems
Wed, 13 Jun 2012 08:32:00 -0700 Redinbaugh MTSD. http://ntecsystems.posterous.com/redinbaugh-mtsd http://ntecsystems.posterous.com/redinbaugh-mtsd

These are before pic of three areas where we have coating that has released from the EPDM. Also attached are pictures of the area that has red algae collected or something and three area where the coating is light where someone marked these to have coating added. Mostly these are fasteners with fabric and the coating has pin holes, very small areas.

Permalink | Leave a comment  »

]]>
http://files.posterous.com/user_profile_pics/2054046/NTEC3.jpg http://posterous.com/users/lD4AHHnGYQjvs NTEC Systems NTECsystems NTEC Systems
Sat, 02 Jun 2012 05:51:51 -0700 Floyd county jail http://ntecsystems.posterous.com/floyd-county-jail http://ntecsystems.posterous.com/floyd-county-jail

Take a look. These are all around the "B" building. Raining pretty hard so we did not access the other systems. I tried to get a shot or two of them in the distance. I will E-mail these also.

-- J D --

Permalink | Leave a comment  »

]]>
http://files.posterous.com/user_profile_pics/2054046/NTEC3.jpg http://posterous.com/users/lD4AHHnGYQjvs NTEC Systems NTECsystems NTEC Systems
Mon, 12 Mar 2012 20:11:58 -0700 520 Mills Ave. http://ntecsystems.posterous.com/520-mills-ave http://ntecsystems.posterous.com/520-mills-ave

Here are the pictures of the HVAC units that will be upgraded.

This is a test!!!

-- JDR --

Permalink | Leave a comment  »

]]>
http://files.posterous.com/user_profile_pics/2054046/NTEC3.jpg http://posterous.com/users/lD4AHHnGYQjvs NTEC Systems NTECsystems NTEC Systems
Mon, 12 Mar 2012 20:06:29 -0700 520 Mills Ave. HVAC upgrades http://ntecsystems.posterous.com/520-mills-ave-hvac-upgrades http://ntecsystems.posterous.com/520-mills-ave-hvac-upgrades Here are the Pictures.

This is a Test !

Permalink | Leave a comment  »

]]>